Flexi Soft Expansion unit Sick FX3-XTIO84002 (1044125)

Flexi Soft Expansion unit Sick FX3-XTIO84002 (1044125)
Производитель: Sick
Артикул: 1044125
Цена: ПО ЗАПРОСУ
Получить скидку и купить со склада↓
   - или -   
Запрос в один клик
   - или -   
Отзывов: 0   Нет оценок   |    Отзывов: 0   |   Поставить свою оценку
Safety controllers
Flexi Soft Expansion unit
 
Model NameFX3-XTIO84002
Part No.1044125
 

at a glance

  • Input expansion modules: eight digital safety inputs and eight test pulse outputs, powered by FLEXBUS+
  • Input/output expansion modules: eight safety inputs and four safety outputs, which can each achieve SIL3, allows fast response time of 8 ms (configuration dependent)
  • Compact, 22.5 mm width

    Преимущества

  • Connection of all common sensors provides greater flexibility
  • Low I/O count per module avoids unused inputs and outputs, saving money
  • Fast-Shut-Off decreases response time. It allows the safety equipment to be closer to the hazardous point and reduces the overall footprint of the machine
     
     
             

    Applications
    Emergency stop pushbuttons:Yes
    Opto-electronic protective devices:Yes
    Non-contact safety switches:Yes
    Two-hand control systems:Yes
    Electro-mechanical safety switches:Yes
    Testable opto-electronic protective devices type 2:Yes
    Operating mode selector switch:Yes
    Control switches with lamp:Yes
    Muting sensors:Yes
    Muting lamp:Yes


    Functions
    Operating mode switching:Yes
    Fast shut-off:Yes
    Safe device communication via EFI/SDL:-


    Electrical data
    Supply voltage:24 V DC (16.8 V DC ... 30 V DC)
    Type of supply voltage:PELV or SELV (the current of the power supply that powers the main unit must be limited to a maximum of 4 A, either through the power supply itself or a fuse.)
    Power consumption:3 W 1)
    Short-circuit protection:4 A gG
    Number of inputs:8 single-channel
    Input voltage HIGH:13 V DC ... 30 V DC
    Input voltage LOW:-5 V DC ... 5 V DC
    Input current HIGH:2.4 mA ... 3 mA3.8 mA
    Input current LOW:-2.5 mA ... 2.1 mA
    Switch-on time of inputs:18 s
    Number of safe outputs:4
    Type of output:PNP semiconductors, short-circuit protected, cross-circuit monitored
    Output current:2 A
    Configuration interface:Internal bus (FLEX BUS+)
    Output voltage HIGH:16 V DC ... 30 V DC
    1) Via FLEX BUS+ without current on X1 ... X8  


    Ambient data
    Protection class standard:EN/IEC 60529
    Enclosure rating terminals:IP 20
    Vibration resistance:5 Hz ... 500 (EN 61131-2)
    Ambient operating temperature:-25 °C ... 55 °C
    Storage temperature:-25 °C ... 70 °C
    Air humidity:10 % ... 95 %, non-condensing
    Climate conditions according to:EN 61131-2 (55 °C operating temperature, 95% rel. humidity)
    Electromagnetic compatibility (EMC):EN 61000-6-2, EN 55011
    EN 61131-2 (zone B)
    Connection type:Cable gland
    Connection type:Plug-in spring terminals
    Dimensions (W x H x D):22.5 mm x 96.5 mm x 120.8 mm
    Weight:164 g
    Protection class according to IEC 60529::IP 40


    Safety-related parameters
    Safety integrity level:SIL3 (IEC 61508), SILCL3 (IEC 62061)
    Category:Category 4 (EN ISO 13849)
    Performance level:PL e (EN ISO 13849)
    PFHd:9.0 * 1E-10
    4.8 * 1E-09
    TM (mission time):20 a



    *изображение на сайте может отличаться от реального
    Нет отзывов об этом товаре.

    Написать отзыв о Flexi Soft Expansion unit Sick FX3-XTIO84002 (1044125)

    Ваше Имя:


    Ваш отзыв:

    Оценка: Плохо           Хорошо

    Введите код, указанный на картинке: