Applications |
| Emergency stop pushbuttons: | Yes | |
| Opto-electronic protective devices: | Yes | |
| Non-contact safety switches: | Yes | |
| Two-hand control systems: | Yes | |
| Electro-mechanical safety switches: | Yes | |
| Testable opto-electronic protective devices type 2: | Yes | |
| Operating mode selector switch: | Yes | |
| Control switches with lamp: | Yes | |
| Muting sensors: | Yes | |
| Muting lamp: | - | |
Functions |
| Operating mode switching: | Yes | |
| Fast shut-off: | - | |
| Safe device communication via EFI/SDL: | - | |
Electrical data |
| Power consumption: | 5 W | |
| Number of inputs: | 8 single-channel | |
| Input voltage HIGH: | 13 V DC ... 30 V DC | |
| Input voltage LOW: | -5 V DC ... 5 V DC | |
| Input current HIGH: | 2.4 mA ... 3 mA3.8 mA | |
| Input current LOW: | -2.5 mA ... 2.1 mA | |
| Configuration interface: | Internal bus (FLEX BUS+) | |
Ambient data |
| Protection class standard: | EN/IEC 60529 | |
| Enclosure rating terminals: | IP 20 | |
| Vibration resistance: | 5 Hz ... 500 (EN 61131-2) | |
| Ambient operating temperature: | -25 °C ... 55 °C | |
| Storage temperature: | -25 °C ... 70 °C | |
| Air humidity: | 10 % ... 95 %, non-condensing | |
| Climate conditions according to: | EN 61131-2 (55 °C operating temperature, 95% rel. humidity) | |
| Electromagnetic compatibility (EMC): | EN 61000-6-2, EN 55011 EN 61131-2 (zone B) | |
| Connection type: | Cable gland | |
| Connection type: | Plug-in spring terminals | |
| Dimensions (W x H x D): | 22.5 mm x 96.5 mm x 120.8 mm | |
| Weight: | 139 g | |
| Protection class according to IEC 60529:: | IP 40 | |
Safety-related parameters |
| Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) | |
| Category: | Category 4 (EN ISO 13849) | |
| Performance level: | PL e (EN ISO 13849) | |
| PFHd: | 4.0 * 1E-10 | |
| TM (mission time): | 20 a | |
*изображение на сайте может отличаться от реального