Applications |
| Type of switching amplifier: | Contact expansion module | |
| Emergency stop pushbuttons: | - | |
| Safety switches: | - | |
| Safety Switch with mechanical lock: | - | |
| Two-hand control systems: | - | |
| Pressure sensitive mats: | - | |
| Opto-electronic protective devices: | Yes | |
| Opto-electronic protective devices without RES/EDM: | - | |
| Opto-electronic protective devices with RES/EDM: | Yes | |
| System part: | Safety relays | |
Functions |
| Input circuit: | Single- or dual-channel | |
Technical data |
| Safety integrity level: | SIL3 (IEC 61508), SILCL3 (IEC 62061) 1) | |
| Category: | Category 4 (EN ISO 13849) 2) | |
| Performance level: | PL e (EN ISO 13849) 3) | |
| B10d parameter: | 1*1E 05 switching cycles (AC-15, 230 V, I = 2 A) 2.5*1E 05 switching cycles (AC-15, 230 V, I = 1 A) 5.4*1E 05 switching cycles (DC-13, 24 V, I = 0.5 A) 1*1E 07 switching cycles (DC-13, 24 V, I ≤- 2 A) | |
| PFHd: | 1.05 * 1E-09 | |
| TM (mission time): | 20 a | |
| Width: | 17.8 mm | |
| Contact type: | Positively driven | |
| Number of enable current contacts: | 2 | |
| Number of signalling current contacts: | 0 | |
| Maximum power consumption DC: | 3.2 W | |
| Type of output: | Relay contacts | |
| Rated operating current (voltage): | 3 A (230 V AC) 4 A (24 V DC) | |
| Maximum switching current: | 6 A | |
| Mechanical life (relay contacts): | 1*1E 07 switching cycles | |
| Electrical life (relay contacts): | 1*10E 05 switching cycles, dependent upon loading, details see operating instructions | |
| Enclosure rating: | IP 20 | |
| Ambient operating temperature from ... to: | 0 °C ... 55 °C | |
| Connection type: | Screw-type terminals | |
*изображение на сайте может отличаться от реального