Applications |
| Type of switching amplifier: | Safety relay | |
| Opto-electronic protective devices: | Yes | |
| Testable opto-electronic protective devices type 2: | Yes | |
| Type of connectable electro-sensitive protective equiqment: | C2000, M2000, single-beam photoelectric safety switches | |
| Number of single-beam photoelectric safety switches from ...: | 1 ... 6 | |
| Number of connectable C2000, M2000 systems: | 3 1) | |
| Number of muting sensors: | 2 ... 4 | |
| System part: | Safety relays | |
Functions |
| Input circuit: | Single-channel | |
| Cross-circuit detection: | Yes | |
| External device monitoring: | Yes | |
| Concurrence monitoring: | Yes | |
| Muting: | Yes | |
| Muting with override: | Yes | |
| Self-testing: | Yes | |
| External test: | Yes | |
Technical data |
| Category: | Type 2 (EN 61496) | |
| Maximum response time: | 5 ms | |
| Operating voltage DC: | 24 V DC | |
| Number of safe outputs: | 2 | |
| Type of output: | PNP, monitored and short-circuit protected | |
| Maximum switching current: | 500 mA | |
| Enclosure rating: | IP 65 | |
| Ambient operating temperature from ... to: | -20 °C ... 60 °C | |
| Connection type: | Spring terminal plug | |