Applications |
| Hazardous point protection: | Yes | |
| Hazardous area protection: | Yes | |
Technical data |
| Enclosure rating: | IP 54 (IEC 60529) | |
| Protection class: | III (EN 50178) | |
| Type: | Type 2 (IEC 61496) | |
| Safety integrity level: | SIL1 (IEC 61508), SILCL1 (EN 62061) | |
| Category: | Category 2 (EN ISO 13849) | |
| Test rate (internal test): | 50 /s (EN ISO 13849) | |
| Maximum demand rate: | 30 /min (EN ISO 13849) 1) | |
| Performance level: | PL c (EN ISO 13849) | |
| PFHd: | 3.2 * 1E-09 | |
| TM (mission time): | 20 a | |
| Maximum protective field range: | 2.12 m 2) | |
| Minimum protective field size: | 40 cm x 40 cm 3) | |
| Maximum protective field size: | 150 cm x 150 cm 4) | |
| Aspect ratio protective field: | 1:1 to 2:1 | |
| Resolution: | 20 mm, 24 mm, 30 mm 5) | |
| Wavelength illumination: | 850 nm | |
| Supply voltage: | 24 V DC | |
| Number of external device monitoring inputs: | 1 | |
| Number of restart interlock inputs: | 1 | |
| Number of teach/sync inputs: | 1 | |
| Switching outputs: | 2 | |
| Power consumption: | 165 mA, 690 mA 6) 7) | |
| Switching current: | 6 mA ... 250 mA | |
| Response time: | 20 ms | |
| Connection type: | M12 x 8 | |
| Dimensions (W x H x D): | 90 mm x 50 mm x 90 mm | |
| Ambient operating temperature from ... to: | 0 °C ... 50 °C | |
*изображение на сайте может отличаться от реального