Applications |
| Safety command devices: | - | |
| Electro-mechanical safety switches: | - | |
| Opto-electronic protective devices: | Yes | |
Functions |
| Safe device communication via EFI/SDL: | - | |
| Reset/restart: | Manual / automatic / configurable | |
Technical data |
| Enclosure rating: | IP 67 (EN 60529) | |
| Ambient operating temperature from ... to: | -25 °C ... 70 °C | |
| Protection class: | III | |
| Safety integrity level: | SIL3 (IEC 61508) | |
| Category: | Category 4 (EN ISO 13849) | |
| Performance level: | PL e (EN ISO 13849) | |
| PFHd: | 9.0 * 1E-09 | |
| TM (mission time): | 20 a | |
| Maximum power consumption: | ≤- 60 mA | |
| Number of safety inputs: | 1 dual-channel | |
| OSSD input voltage HIGH: | 13.5 V, 24 V, 28.8 V | |
| OSSD input test pulses: | 0 Hz ... 25 Hz | |
| OSSD input test pulse width: | 0 µs ... 550 µs | |
| AS-Interface profile: | S-O.B.E | |
| AS-Interface version: | 2.1 | |
| Data bits IN input channel I1: | AS-Interface Safety at Work code sequence on D0, D1 | |
| Data bits IN input channel I2: | AS-Interface Safety at Work code sequence on D2, D3 | |
| Data bits OUT LED alarm: | Not used | |
| AS-interface voltage range: | 26.5 V DC ... 31.6 V DC | |
| Supply voltage AUX PWR: | 16.8 V, 24 V, 28.8 V | |
| Minimum opening time for the contacts socket I1/2: | 51 ms | |
| Output current Pin 1 (AUX L+): | 1.4 A | |
| Cable capacitance socket I1/2: | 100 pF | |
| Maximum response time: | 22 ms | |
| ESPE sender total output current (AUX L+): | 1.4 A | |
Electrical data |
| Fieldbus: | AS-Interface Safety at Work | |
*изображение на сайте может отличаться от реального