Applications |
| Safety command devices: | Yes | |
| Electro-mechanical safety switches: | Yes | |
| Non-contact safety switches: | Yes | |
| Opto-electronic protective devices: | Yes | |
| Two-hand control systems: | Yes | |
| Operating mode selector switch: | Yes | |
| Muting sensors: | Yes | |
| Muting lamp: | Yes | |
Functions |
| Safe device communication via EFI/SDL: | Yes | |
| Reset/restart: | Manual / automatic / configurable | |
Technical data |
| Enclosure rating: | IP 67 | |
| Ambient operating temperature from ... to: | 0 °C ... 55 °C | |
| Protection class: | III | |
| Safety integrity level: | SIL3 (IEC 61508) | |
| Category: | Category 4 (EN ISO 13849) | |
| Performance level: | PL e (EN ISO 13849) | |
| PFHd: | 1.33 * 1E-09 | |
| TM (mission time): | 20 a | |
| Maximum power consumption: | ≤- 9 A | |
| Number of safety inputs: | 8 dual-channel or 16 single-channel | |
| Input voltage HIGH field signal inputs: | 11 V, 24 V, 28.8 V | |
| Input delay field signal inputs: | Configurable 0 ... 90 ms | |
| Number of test/signal outputs (with current monitoring): | ≤- 16 (2) | |
| Number of SDL connections: | 2 | |
| Output voltage HIGH field signal outputs: | UV, without load, switched-on | |
| Output current field signal output: | 0 mA ... 700 mA | |
| Minimum current for fault monitoring: | 7 mA ... 40 mA, on field-signal connections 7 and 8 1) | |
| Maximum current SDL connections: | 1.4 A | |
| Maximum internal resistance SDL connections (power supply): | 0.3 Ω- | |
| Input voltage HIGH SDL connections (OSSD inputs): | 13 V, 24 V, 28.8 V | |
| Maximum test puls rate SDL connections (OSSD inputs): | 500 Hz | |
| Maximum test pulse width SDL connections (OSSD inputs): | 700 µs | |
| Baud rate PROFIBUS connection: | 9.6 kbit/s ... 12 Mbit/s | |
| Address range PROFIBUS connection: | 3 ... 125 | |
| Ident number PROFIBUS: | 071A hex | |
Electrical data |
| Fieldbus: | PROFIBUS PROFIsafe | |
| Supply voltage: | 19.2 V DC, 24 V DC, 28.8 V DC | |
*изображение на сайте может отличаться от реального