Functions |
| Restart interlock: | Yes | |
| Restart interlock (delivery status): | Deactivated | |
| External device monitoring: | Yes | |
| External device monitoring (delivery status): | Deactivated | |
| Beam coding: | Yes | |
| Bypass (with UE402): | - | |
| Operating mode switching (with UE402): | - | |
| Type of blanking: | No | |
| Reduced resolution: | - | |
| SDL interface: | - | |
| Muting with: | Flexi Classic, Flexi Soft | |
| Configuration method: | hard wired | |
| Extension connection: | - | |
| PSDI mode with: | Flexi Soft | |
| Safe device communication via EFI/SDL: | - | |
Technical data |
| Protective field height: | 120 mm | |
| Resolution: | 34 mm | |
| Scanning range from ... to: | 0 m ... 6 m | |
| Scanning range typ.: | 0 m ... 8 m | |
| Housing length: | 120 mm | |
| Housing cross-section: | 15 mm x 32 mm | |
| Weight: | 50 g | |
| Type: | Type 2 (IEC 61496) | |
| Safety integrity level: | SIL2 (IEC 61508), SILCL2 (IEC 62061) | |
| Category: | Category 2 (EN ISO 13849) | |
| Test rate (internal test): | 58 /s (EN ISO 13849) | |
| Maximum demand rate: | 34 /min (EN ISO 13849) 1) | |
| Performance level: | PL d EN ISO 13849 | |
| PFHd: | standalone system: 2.4 * 1E-08 (EN ISO 13849) | |
| TM (mission time): | 20 a | |
| Enclosure rating: | IP 65 | |
| Protection class: | III (EN 61140) | |
| Ambient operating temperature from ... to: | -20 °C ... 55 °C | |
| Vibration resistance (checked to): | 5 g (IEC 60068-2-6) | |
| Oscillation frequency from ... to: | 10 Hz ... 55 Hz | |
| Shock resistance: | 10 g, 16 ms (IEC 60068-2-29) | |
| Response time: | 13 ms 2) | |
| Supply voltage typical, from, to: | 24 V DC, 19.2 V DC, 28.8 V DC | |
| Maximum switching current: | 300 mA | |
| Wave length: | 850 nm | |
| Maximum connection cable cross-section: | 0.34 mm? | |
| Cable length: | 160 mm | |
| Mounting system type: | C-fix or L-fix bracket | |
| Extension connection usage: | Stand alone | |